HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

Zhejiang Shengdi Technology Inc.

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

  • 1
  • 2
  • 3

Brand Name : SHENGDI TECHNOLOGY

Model Number : HS-6303

Certification : CNAS,SGS.

Place of Origin : ZHEJIANG.CHINA

MOQ : 1 SET

Price : USD$1~100000/SET

Payment Terms : L/C, T/T

Supply Ability : 50 SET/PER MONTHS

Delivery Time : 35~45Days

Packaging Details : WOODEN CASE

Accuracy : 0.05% Class

Voltage : 50~480V

Positions : 6 Positions

Current Source : 3* 1mA-200A

Meter : Single Three Phase Meter

Contact Now

HS-6303 three-phase energy meter testing bench

SUIT FOR "CT METER" & Single-phase/Three-phase meter

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

HS-6303 three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.

This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

  • base on A/D and DSP technology
  • adopt precise digital synthesized technology and sine PWM technology
  • adopt intelligent system control technology, multi-CPU coprocessing technology
  • reliable multi-path pulse testing and precise error testing treatment technology
  • SPWM technology power amplifier, large capacity, high performance, low power consumption, automatic warning protection
  • Error processor of each station distributed networking, heavy current protection, support multi-path pulse signal input
  • Can configurate serial server, implement parallel communication of multi-station, improve work efficiency
  • Modular design, have good universality of parts, easy to disassemble and maintain
  • One-button checking and control management system, automatic finish as per the project
  • Standard cabinet, aluminum alloy frame, nicer and stronger
  • Customized as per specific function

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

CLASS 0.02 0.05 0.1
Reference standard energy meter HS-5300H 0.02 HS-5300 0.05 HS-5300 0.1
Output range

Voltage:3×30~300V

Current:3×1mA~120A

Voltage:3×30~300V

Current:3×10mA~120A(200A Option)

Output phase shift 0~360°,resolution:0.01°
Output frequency 45~65Hz ,resolution:0.01Hz
Waveform distortion Both Voltage and current<0.5%( relative liner load)
Voltage &current power stability

<0.02%/120s

<0.05%/120s

<0.1%/120s

Output capacity

Voltage:300VA(6 stations)

Current:250VA(120A)

Voltage:300VA(16 stations)current:900VA(120A)
if add meters, Max. current: 2000VA,Max. voltage: 1200VA

Load characteristics Resistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF)
Starting up current output Min.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5%
sampling pulse input ≤1kHz
Communication testing RS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107
Number of energy meters to be tested 6/16(standard),3-60 (optional)
Environment condition temperature:20℃±5℃;humility:<85% R.H.
Power supply

AC220 ±10%,50/60Hz,AC120/240V(optional);
Max. power consumption:3000VA(24 stations)

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

Integration stations Number of rack dimension:L×W×H Fission stations Number of rack dimension:L×W×H
6 1 2000×800×1600 12 1 2000×700×1920
CUSTOM 16 1 2200×700×1920
12 1 2000×800×1920 24 2 2000×700×1920
16 1 2200×800×1920 32 2 2200×700×1920
24 2 2000×750×1920 cabinet 600×800×1920

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

Description Range of application
HS-6303 three-phase energy meter testing bench Standard energy meter testing
HS-6303B three-phase multi-function energy meter testing bench Multi-function energy meter testing
HS-6303C three-phase horizontal energy meter calibration bench Energy meter error calibration
HS-6303E three-phase energy meter test bench with ICTS 1P3W energy meter testing
HS-6303F three-phase intelligent energy meter testing bench intelligent energy meter testing
HS-6303G three-phase energy meter (round meter) testing bench Standard energy meter testing
HS-6303M three-phase din-rail energy meter testing bench Multi-function energy meter testing
HS-6303H three-phase high precision energy meter testing bench Energy meter error calibration

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

Function item

HS-6303

HS-6303B

HS-6303C

HS-6303E

HS-6303F

HS-6303G

HS-6303M

HS-6303H

Base testing

functions

Base error
Creep testing
Starting up testing
standard deviation
Constant calibration
Counting error
Influencing testing
Multi-function testing Daily timing error☆
Period switching
Demand period error
Demand display error
Energy display error
register checking
GPS clock synchronization☆
Communication testing☆
  • :●─standard;〇─optional.

For Item ☆ need special function parts

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

Type

HS-6303

HS-6303B

HS-6303C

HS-6303E

HS-6303F

HS-6303G

HS-6303M

HS-6303H

Standard energy meter
power source
error processing system
multi-path pulse input
Auto searching mark
auto short circuit
ICT
parallel communication
carrier communication
IR communication
power consumption testing
DC and even harmonic wave
standard clock tester
GPS clock synchronization
collective turn over & optoelectronic sampling
  • :●─standard;〇─optional

PRODUCTS DETAILS:

Technical Specification:
Kwh meter test bench with capacity to test at least 6 energy meter in one single batch comprising of following functions:
1.Ability to test single phase and three phase KWH meters for
★Constant test(Register test)
★ Error test
★No-load test
★Creep test
★Start Test
★ Variation tests for voltage,frequency and harmonics test
2. Manual control with tablet or Computer through a delicated software
3. Individual adjustment for voltage,current and phase angles
4.Range:
★ Voltage range: 3*30~300V
★ Current range:3*0.01~120A
5.Voltage and current adjustment limit:0%~120% if range.
6.Phase adjustament limit: 0~360°
7.Frequency adjustment limit: 45Hz~65Hz
8.Power Stability:≤0.05%/120s
9.Distortion:≤0.5%
10.Harmonic Setting: 2~21st Harmonic,Content:≤40%
11.Active power phase shift:0~360°
12.Power supply: AC220V +/-10%,50/60Hz.
Ask for pirce: hysdsales@gmail.com
HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy
HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

CALIBRATION CERTIFICATION

As customer's requirement,we can supply 3rd part calibration certification. with CNAS mark.

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracyHS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy


Quality HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy for sale

HS-6303 Single Three Phase KWH Meter Test Bench,6 Position,0.01~100A current,0.05% accuracy Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhejiang Shengdi Technology Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)